Grid Solutions S.p.A. CEME HV Lab.

Via A. Meucci, Nº. 22
Noventa di Piave, VE, 30020
Italy

Open Google map

Overview

Key Contact Personnel:
Eros Stella, Head of Laboratory eros.stella@ge.com
Roberto Pistolato, Head of Quality roberto.pistolato@ge.com

Total Number of Employees: 8

Major Export Markets Served: Italy, China, Brazil, France, Germany

Services

High Voltage Laboratory

Dimensions of Main Test Hall: 
25 m length x 25 m width x 25 m height

Dimensions of Secondary Test Hall: 
15 m length x 5 m width x 7 m height – 1,100 m2 (outdoor)

Dielectric Testing Facilities

Impulse Testing

Max. Volt./Current

Standard

Lightning Impulse

2500 kV

62271-1 60060-1

Switching Impulse (Dry)

1200 kV

62271-1 60060-1

Switching Impulse (Wet)

1200 kV

62271-1 60060-1

A.C. Testing

Dry/Wet

800 kV rms

62271-1 60060-1

RIV Testing: Class 550 kV rms 62271-1 60060-1

Other Tests Performed on Insulators, Bushings:

Mechanical tests, temperature rise test; thermal stability test Ref. IEC 60168 and IEC 60137
DC temperature rise test single-phase up-to 10kA
Corona test and UV detection via UV camera


Other Test Capabilities:

Mechanical Tests:Up to 420 kV – IEC 60168
Mechanical Test Facilities:
1100 m2 for outdoor installation
Installation up to 25 m heght with terminal load application max 20 kN
Accoustic Measurement: For CB and DSC